Max10: ADC no longer working that have .pof document

Max10: ADC no longer working that have .pof document

Sorry, you should be certain that to do this action. Delight click on the confirmation link on your email address. It’s also possible to lso are-send throughout your profile.

  • Intel Neighborhood
  • Product Support Message boards
  • FPGA
  • Automated Products
  • Max10: ADC not working that have .pof document
  • Draw Procedure because the The brand new
  • Draw Matter due to the fact Understand
  • Float this topic having Current Member

We believe you really have you to definitely (or even more) somewhat slow or not as much as rated offers

I’m already coping with Max10M16DAF256 and i also have a problem with new ADC. sof document it really works okay. pof file the ADC does not work anymore, we.age ADC information is usually zero, given that someone else portion performs precisely.

While using

I have including seen that after programming with .pof file but still allow the suppy voltage on, the newest ADC works. But just after reset the supply voltage (switch off and on once more), it generally does not really works more.

In case the latter you will need to ensure view the manner in which you launch brand new ADC Ip regarding reset. Hold on a minute in reset ‘a little longer’ after the power up. Disappointed this may voice a little obscure. So it appears to be a typical procedure with the discussion board one to does not appear to have gotten an obvious, reputable services.

Should this be their panel then you need to test the above and make certain new rails rise monotonically. There aren’t any sequencing requirements but if the you should never go up correctly – perhaps not conference this new Tramp day – the machine commonly misbehave. Refer to ‘Figure 3. Monitored Electricity Supplies Ramp Up’ regarding the ‘ strength administration member book (

In addition discover the same trouble with Max10 ADC an additional bond, however, like you told you there’s no services for it.

The newest panel try our very own notice construction board. The problem is that many of our very own chatrooms will work okay that have ” .pof “-file, and many of these get this ADC condition. Towards the forums which have ADC disease, we investigated on resources of those forums regrettably i missed any problem towards the gear. Such as mentioned above, the chat rooms are working that have ” .sof ” and even ” .pof “-document when the likewise have current is towards. After the supply current was reset, the fresh new ADC really does don’t really works given that people remains functioning accurately.

This will make me personally faith a whole lot more this dilemma may be stamina associated. You might be clearly towards side of no matter what concern is given you may have doing work forums.

Could you just take a low functioning panel, disconnect the advantage provides and energy they away from workbench offers? My issue is that a not as much as rated train isn’t really around providing the Katowice women beautiful inrush requisite and dips resulting in the POR circuitry a great disease, and this (perhaps) isn’t really recorded.

You might be proper. I did certain data from the electricity offers to own Max10, plus it appears to be all of our analogue supply takes a bit enough time up to they is at complete voltage peak (the audience is using Max10 dual have product, and that means a few electronic offers and you will step 1 analogue also have).

Like in Max10 Strength government associate publication, it looks like just the past power to possess Max10 count (affixed image), therefore we attempted to swtich toward analogue also have very first and you can await it to arrive maximum top, right after which start others a couple of digital offers, and this capture only pair hundred or so µs to arrive maximum level. This helps the maybe not-working ADC to be functioning sporatically (not always performing).

Nevertheless when we bring a functional board (ADC constantly performs) and perform the reverse succession (we.age let a couple of digital provides to your earliest, then your analog have), the fresh new ADC remains working (i asked it ought not to work any further).

Thus for some reason the new ADC condition refers to the advantage supply series therefore the ramp duration of energy provides, but a very clear reasons for it state could have been perhaps not discovered yet ,.